伊人影视,亚洲爆乳无码一区二区三区,久久av,欲妇荡岳丰满交换


免費注冊快速求購


分享
舉報 評價

顯微鏡溫度控制器

參考價面議
具體成交價以合同協議為準

該廠商其他產品

我也要出現在這里

詳細信息 在線詢價

詳細介紹

H401-T-CONTROLLER 顯微鏡溫度控制器

 

2-Channel Temperature Controller with 4.3'' touch screen interface compatible with all H401 heating devices. One controller can control independently up to two items.

External temperature sensor (included) and self calibration routines allows easy calibration of the heating devices for the highest accuracy on sample temperature.

On board data logging and download procedures to USB drives allow to record temperature as a function of time and to log calibration events and alarms.

The controller is equipped with password protected routines to re-calibrate the sensors against certified thermometers.

 

Features

T - rangefrom ambient to 60°C
T - accuracy on specimen± 0.3°C
External T - sensor (included).
On-board Data logging and download routines to USB drive. 
On-board logging of calibration and alarm events.
Alarm buzzer and External Alarm Connector
One controllers can control independently up to two devices.
Self calibration routines allow to improve temperature accuracy.
Password protected procedure for periodic calibration against certified thermometer
Integrated in third party softwareNikon NIS Elements; Metamorph; Micromanager

 

H401-T-PAD

The Heated Flat Metal Plate can be positioned on any surface (Table Top, Cabinet work surface, etc) to create a temperature controlled flat surface.

 

Features

T range27 to 45°C

T sensor accuracy±0.1°C

T accuracy on specimen±0.3°C, after self calibration, if room temperature remains within ±1°C

Plate calibration can be performed in the lab by the operator

Dimensions:

174x234 mm        H401-T-PAD-SMALL
297x210 mm (A4) H401-T-PAD-MEDIUM
420x300 mm (A3) H401-T-PAD-LARGE
 

H401-GLASS TABLE

The ITO glass table realizes a flat and transparent surface at controlled temperature. Ideal for stereo microscopes.

It requires H401-T-CONTROLLER.

 

Features

T rangeambient to 60°C
T sensor accuracy±0.1°C
T accuracy on specimen±0.3°C, after self calibration, if room temperature remains within ±1°C
4.3'' touch screen interface
On-board data logging and download routines to USB drive
Plate calibration can be performed in the lab by the operator
Glass thickness2 mm
Adjustable height:
from 31 to 37 mm
from 75 to 105 mm

 

 

 

H401-K-FRAME-METAL-GLASS

The Glass side of the Metal Glass T Plate creates a warm and optically transparent surface perfectly flush with the microscope stage. It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The glass is chemically strengthened and protected by a rigid aluminum frame.

The metal side of the Metal Glass T Plate features a trimmed 24 mm diameter observation opening for imaging with oil immersion lenses.

The metal and glass sides have independent temperature sensors for independent temperature control of each side.

It requires H401-T-CONTROLLER. Uses both channels. 

Features

Flush with stages with k-frame insert (160x110mm), compatible with the following XY stageMarzhauser (all models), Ludl (all models), ASI (all models, including z-piezo), Prior H107 and H117, Leica (k-frame), Zeiss (k-frame), Olympus (k-frame)
Temperature rangefrom ambient to 60°C
Accuracy on specimen± 0.3°C
4.3'' touch screen interface
On-board data logging and download routines to USB drive
ITO glass side thickness0.5 mm, chemical glass strengthening ensures highest resistance
Easy plate replacement, if necessary
Flat respect to the rest of the XY stage
Uses both channels of the dual controller H401-T-CONTROLLER

 

H401-K-FRAME-METAL-FLAT

The Metal T Plate creates a warm flat temperature controlled surface perfectly flush with the microscope stage and features a circular observation opening in the center. It employs a surface sensor to ensure the highest accuracy on temperature reading.

 

 

H401-NIKON-TI-S-ER-METAL

The Metal T Plate creates a warm flat temperature controlled surface at the same height as the rest of the XY stage perfectly flush with the microscope stage. It employs a surface sensor to ensure the highest accuracy on temperature reading.

 

 

FULL STAGE HEATER

The Stage Heater covers the entire XY stage and provides a flat, smooth surface at controlled temperature. It clamps on the stage and it is fixed in place by set crews positioned on the vertical sides of the plate. The Stage Heater leaves the observation hole open.

It is possible and recommendable to use the Stage Heater in combination with Glass Heated Insert. In this configuration, the H401-T-CONTROLLER uses one channel to control the metal PAD and the other channel to control the Glass Insert. Models available for Nikon and Olympus stages.

It requires H401-T-CONTROLLER.

Features

Clamps on the stage and creates a flat surface at constant T
Temperature rangefrom ambient to 45°C
Accuracy±0.3°C
4.3'' touch screen controller
On-board Data logging and download routines to USB drive
Compatible with Glass Plates
Easy to fix on stage
Models available for:
NIKON-TI-SR               (code H401-NIKON-TI-SR-T-PAD)
NIKON-TS2R                (code H401-NIKON-TS2R-T-PAD)
OLYMPUS-IX-SUSP       (code H401-OLYMPUS-IX-SUSP-T-PAD)

 

 

 

    

    

    

         

    

    

    

    


同類產品推薦


提示

×

*您想獲取產品的資料:

以上可多選,勾選其他,可自行輸入要求

個人信息: