新勢力光電供應Wilks油脂分析儀,是一種簡便而準確的紅外在線分析方法,用于檢測:水中的油(TOG, Total Oil and Grease)、土壤中的石油烴(TPH, Total Petroleum Hydrocarbons)、廢水中的油脂(FOG, Fats, Oil and Grease)。該系列TOG/TPH油脂分析儀FOG/TOG油脂分析儀具有如下特點:檢測速度快(10-15分鐘)、檢測范圍寬(0.1ppm-5000ppm 脂肪烴和芳香烴)、結構緊湊(165×165×127mm³, 2.2kg)、檢測標準嚴格(ASTM D7066和EPA 166),目前在范圍超過3000套的使用量,已經成為油脂檢測和監控的行業標準。依據檢測靈敏度和提取溶劑的區別,如下型號可供選擇:InfraCal Model HATR-T2、InfraCal Model CVH、InfraCal Model CH、InfraCal 2 Model ATR-SP、InfraCal 2 Model TRANS-SP。

 

Model

InfraCal
Model HATR-T2

InfraCal
Model CVH

InfraCal 2
Model ATR-SP

InfraCal 2
Mode TRANS-SP

Technology

3.4μm fixed filter infrared analyzer

Min detection Water

8 ppm

2 ppm

0.3 ppm

0.1 ppm

Min detection Soil

40 ppm

10 ppm

3 ppm

1 ppm

Solvent

Hexane, Pentane, Cyclohexane, Vertrel MCA

Perchloroethylene,
S-316, Freon-113

Hexane, Pentane, Cyclohexane, Vertrel MCA

Perchloroethylene,
S-316, Freon-113

Components measured

Hydrocarbons with boiling point higher than solvent

All hydrocarbons

Hydrocarbons with boiling point higher than solvent

All hydrocarbons

Method complies

N.A.

ASTM D7066,
EPA 413.2, EPA 418.1

N.A.

ASTM D7066,
EPA 413.2,

EPA 418.1

Method compares

EPA 1664, ISO 9377-2

EPA 1664, ISO 9377-2

EPA 1664, ISO 9377-2

EPA 1664,

ISO 9377-2

Volatile componets

Loses

Includes

Loses

Includes

Data acquisition

Printer from Wilks

Printer from Wilks

Internal data
storage & export

Internal data
storage & export

Calibrations

Single

Single

Multiple

Multiple

Display

4 character LED

4 character LED

Touch screen

Touch screen

Password protection

No

No

Yes

Yes

Battery pack

External

External

Internal

Internal

Others

Solvents lighter than water, sample collected form container top

Solvents heavier than water, requires separatory funnel or septa cap vial

Solvents lighter than water, sample collected form container top

Solvents heavier

than water,

requires separatory funnel or septa

cap vial

 

Model

P/N

Description

Min Detection 8 ppm

405-1009

Includes 100 mrcroliter sypringe, Un-calibrated

InfraCal
Model HATR-T2

405-1009-44

Factory calibrated using 403-1044

403-1044

TOG/TPH calibration standard set

405-1009-72

Factory calibrated using 403-1072

403-1072

FOG/TOG calibration standard set

403-1067

InfraLog serial printer

403-0013

Carrying case

403-0003

External 12V battery pack

403-0002

12V automotive power adapter cable

403-0005

Dust cover

403-1011

Field sampling kit

Min Detection 2 ppm

405-0003/12

Includes set of 4-10mm cuvettes, Un-calibrated

InfraCal
Model CVH

405-0003/12-41

Factory calibrated using 403-1041

403-1041

S-316 TOG/TPH calibration standard set

405-0003/12-40

Factory calibrated using 403-1040

403-1040

S-316 FOG/TOG calibration standard set

405-0003/12-78
405-0003/12-64

Factory calibrated using 403-1064

403-1064

Tetrachloroethylene (Perchloroethylene) TOG/TPH calibration standard set

403-0012

Set of 4-10mm quartz cuvette cells

403-1067

InfraLog serial printer

403-0013

Carrying case

403-0003

External 12V battery pack

403-0002

12V automotive power adapter cable

403-0005

Dust cover

403-1063

Field sampling kit

Min Detection 0.3 ppm

405-2034

Includes set of 4-10mm cuvettes, Un-calibrated

InfraCal 2
Model ATR-SP

405-2034-81

Factory calibrated using 403-1081

403-1081

Hexane TOG/TPH calibration standard set (Low range)

405-2034-44

Factory calibrated using 403-1044

403-1044

Hexane TOG/TPH calibration standard set (High range)

405-2034-8144

Factory calibrated using 403-1081 and 403-1044

405-2034-72

Factory calibrated using 403-1072

403-1072

Hexane FOG/TOG calibration standard set

403-0013

Carrying case

403-1011

Field sampling kit

Min Detection 0.1 ppm

405-2035

Includes set of 4-10mm cuvettes, Un-calibrated

InfraCal 2
Model TRANS-SP

405-2035-80

Factory calibrated using 403-1080

403-1080

S-316 TOG/TPH calibration standard set (Low range)

405-2035-41

Factory calibrated using 403-1041

403-1041

S-316 TOG/TPH calibration standard set (High range)

405-2035-8041

Factory calibrated using 403-1080 and 403-1041

405-2035-40

Factory calibrated using 403-1040

403-1040

S-316 FOG/TOG calibration standard set

405-2035-79

Factory calibrated using 403-1079

403-1079

Tetrachloroethylene (Perchloroethylene) TOG/TPH calibration standard set (Low range)

405-2035-78

Factory calibrated using 403-1078

403-1078

Tetrachloroethylene (Perchloroethylene) TOG/TPH calibration standard set (High range)

405-2035-7978

Factory calibrated using 403-1079 and 403-1078

403-0012

Set of 4-10mm quartz cuvette cells

403-0013

Carrying case

403-1063

Field sampling kit

403-1083

Field sampling kit for sub-ppm


/strong>

相關商品


    • InfraSpec VFA-IR光譜儀

    • Wilks生物燃料分析儀

    • InfraRan氣體分析儀

    • InfraCal Soot Meter煙塵儀
    •  
    •  



提示

×

*您想獲取產品的資料:

  • 價格、產地、生產者、用途、性能
  • 生產日期、有效期限、檢驗合格證明
  • 規格、等級、主要成份
  • 使用方法說明書、售后服務
  • 其他
以上可多選,勾選其他,可自行輸入要求

個人信息:

  • *聯系人
  • 公司名稱
  • *聯系電話
  • 聯系郵箱